Portable Gas Monitor
GW-3 series
GW-3(O2)
Features
・Among world's smallest and lightest
・One-year sensor warranty
・Newly developed R sensor installed for improved
performance.
Sampling method |
Diffusion type/Single type |
Principle of detection |
Membrane Type Galvanic Cell Method |
Detection range |
0.0 to 25.0 vol% |
Alarm setpoints |
L 18.0 vol% LL 18.0vol% H 25.0vol% |
Type of alarm |
Gas alarm / fault alarm |
Display of alarm |
Flashing lamp / buzzer / flashing gas concentration readout / vibration |
Explosion protected construction |
Intrinsic safety |
Explosion-proof class |
IECEx : Ex ia ⅡC T4 Ga |
Ingress proof rating |
IP66/68(2m, 1h) |
Approvals |
Japan Ex, ATEX, IECEx, China Ex, JIS |
CE marking |
EMC / ATEX / RoHS |
Power source |
CR2450 coin type lithium battery |
Continuous operation |
Approx. 4000 hours |
Dimensions |
Approx. 63(W)×42(H)×22(D) mm (excluding projections) |
Weight |
Approx. 45 g |
Operating temperature range |
-20 to +50 ℃ (no sudden changes) |
Operating humidity range |
10 to 90 %RH (no condensation) |
|
undefined |
4732 9320 10
Wristwatch belt
4711 7125 00
Heat-resistant case
*This cover is non-explosion proof.
4711 7124 20
Leather case
4732 5006 70
Alligator clip
4732 9285 90
Calibration cap
4123 9703 10
Arm band
0888 0605 90
Hand strap
9811 08
Data logger management program