Smart Transmitter / Gas Detector
SD-1 series
SD-1RI, SD-1DRI
Features
・ATEX / IECEx certificate
・Flameproof enclosure for Acetylene and Hydrogen
・Self diagnosis by microprocesso
Model list
SD-1RI (Diffusion type)
  SD-1DRI (Suction type)
▶DTM software Download
| Sampling method | Suction type/Single type, Diffusion type/Single type | 
| Principle of detection | Non-Dispersive Infrared Method | 
| Detection range | 0 to 100 %LEL | 
| Alarm setpoints | 25%LEL | 
| Type of alarm | Gas alarm / fault alarm | 
| Display of alarm | Lamp lighting / information displayed | 
| Explosion protected construction | Flameproof enclosures | 
| Explosion-proof class | IECEx : Ex db ⅡC T6 Gb | 
| Ingress proof rating | IP65 | 
| Approvals | Japan Ex, ATEX, IECEx, Brazil Ex, Taiwan Ex, China Ex, SIL | 
| CE marking | EMC / ATEX / RoHS | 
| Power source | 24 VDC±10 % | 
| Dimensions | Approx. 148(W) × 161(H) × 88(D) mm [SD-1RI] | 
| Weight | Approx. 2.0 kg [SD-1RI] | 
| Operating temperature range | Depend on Detectable gas (no sudden changes) | 
| Operating humidity range | 0 to 95 %RH (no condensation) | 