Discontinued

Post Product

Portable Gas Monitor

GX-8000 series

GX-8000

Features

・Easy carrying due to small size and lightness.
・Large screen with backlight easy to see.
・Display the concentration with both the value and the bar
 meter.
・Solid structure strong to impact and dirt.

GX-8000

360 view

Sampling method

Suction type/Double type

Principle of detection

New Ceramic catalytic Method, Thermal Conductivity Method, Potentiostatic Electrolysis Method, Membrane Type Galvanic Cell Method

Detection range

0 to 100 %LEL / to 100 vol% (combustible gas)
0 to 40 vol% (0 to 25 vol%) (O2)
0 to 100 ppm ( 0 to 30 ppm) (H2S)
0 to 500 ppm (0 to 150 ppm) (CO)

Type of alarm

Gas alarm / fault alarm

Display of alarm

Lamp blinking / buzzer / gas concentration display blinking

Explosion protected construction

Intrinsic safety

Explosion-proof class

IECEx : Ex ia IIC/IIB T4 Ga
ATEX : Ⅱ1G Ex ia IIC/IIB T4 Ga

Ingress proof rating

IP67

Approvals

Japan Ex, ATEX, IECEx, JG

CE marking

EMC / ATEX / RoHS

Power source

Lithium ion battery unit or
Dry battery unit (AA alkaline battery 3pcs.)

Continuous operation

Approx. 12 hours [Lithium ion battery unit]
Approx. 6 hours [Dry battery unit]

Dimensions

Approx. 154 (W) × 81 (H) × 127 (D) mm (excluding projections)

Weight

Approx. 1.1 kg [Lithium ion battery unit]
Approx. 1.0 kg [Dry battery unit]

Operating temperature range

-20 ℃ to +50 ℃ (no sudden changes)

Operating humidity range

0 to 95 %RH (no condensation)

Target gas
1-C5H10, ALD, C2H2, C2H4, C2H5OH, C2H6, C3H6, C3H6O, C3H8, C4H10O, C4H6, C4H8, C5H10, C5H8, C5H8O2, C6H6, C7H14, C7H8, C8H10, CH3CN, CH3OH, CH4, CO, DME, EO, EtAc, H2, H2S, i-C4H10, i-C4H8, IBA, IPA, MEK, MIBK, MMA, n-C4H10, n-C5H12, n-C6H14, n-C7H16, O2, PO, THF, VAc

Filter tube

4777 9007 30

Filter tube fixing belt

4775 9679 50

Gas sampling hose (with plummet, 30m)

4384 0430 60

Gas sampling hose (with float probe, 8m)

0904 0186 20

Water trap

1641 0190 20

Demand flow valve

Waist belt and waist belt attachment

4775 5649 90

Carrying case

4775 9860 80

Aluminum trunk case

4775 9885 20

Shipboard storage box

4775 5651 00

Sampling probe holder

4777 9025 70

Protective film

0904 0103 80

Gas sampling bag 1L (for %LEL)

9811 04

Dataloggermanagementprogram