GX-Force - Portable 4 Gas Detector | RIKEN KEIKI CO., LTD.

High
Sustainability

NEW STANDARD
Portable 4Gas Detector

MODEL:
SCROLL

GX-Force
Sustainability

The GX-Force was developed as a portable four gas detector offering high quality and usability.
Unlike disposable gas detectors, it can be used repeatedly without disposal.

GX-Force Sustainability

Features

  • Weight:Approx. 300 g

    Weight: Approx.

    300g
  • Continuous operation:Approx. 30 hours

    Continuous
    operation: Approx.

    30 hours
  • Sensor Warranty: 3years

    Sensor Warranty:

    3years
  • Passes 3m drop testing

    Passes

    3m

    drop testing

  • Protection rating equivalent to IP67

    Protection rating
    equivalent to

    IP67
  • Operating temperature range -40°C-+60°C (temporary use environment)

    Operating
    temperature range

    -40℃-+60℃ (temporary use environment)

Wide range of safety functions

Combustible gas conversion functionCombustible gas conversion function

Eliminates the need for troublesome calculation. Allows direct of 27 different combustible gas types.
*Setting are retained even when power is turned on and off.

Combustible gases conversion list
Gas type Conversion
from CH4
models
Conversion
from HC
models
Methane ×
Isobutane
Hydrogen
Methanol
Acetylene
Ethylene
Ethane ×
Ethanol
Propylene
Gas type Conversion
from CH4
models
Conversion
from HC
models
Acetone
Propane ×
Butadiene
Cyclopentane
Benzene
N-hexane
Toluene
N-heptane
Xylene
Gas type Conversion
from CH4
models
Conversion
from HC
models
N-nonane
Ethyl acetate
Isopropyl
alcohol
Methyl
ethyl ketone
Methyl
methacrylate
Dimethyl
ether
Methyl
isobutyl
ketone
Tetrahydrofuran
Normal
pentane

Alarm setpoint setting functionAlarm setpoint setting function

Setting can be changed/configured on the GX-Force main unit. Supports control and management in accordance with the customer’s own criteria.

Confirmation beep functionConfirmation beep function

Indicates that the product is functioning normally. The buzzer sounds at preset intervals while measurement is underway.

Calibration notification functionCalibration notification function

Indicates the number of days until recommended regular maintenance when the power is turned on. Reminds the user to perform maintenance to ensure safe use.

Wide range of safety functions

New R Sensor for outstanding long-item stability

The GX-Force incorporates/utilizes the newly developed R Sensor series.
The R Sensor features dramatically improved performance over conventional sensors.
The sensors are covered by a 3-year warranty* for peace of mind.

*Assumes the sensor is inspected at least once a year.
  • Combustible gas

    Combustible gas

    Though construction with excellent toxicity and impact resistance

  • O2

    O2

    Electrochemical type with greatly improved basic characteristics

  • CO & H2S

    CO & H2S

    2-in 1 dual construction for compact main unit

  • CO

    CO

    Two-sensor configuration minimizes H2 interference

High Usability

Usability01

For measurement inside tanks:checking safety before entry

Before working in the confinement space, the oxygen concentration and toxic gas inside can be checked to ensure safety.

For measurement inside tank
For measurement inside tank

Usability02

For the safety around workers

Despite its built-in pump, the lightweight and compact design allows it to be used without getting in the way of work.

For environmental

Usability03

For taking measurements at specific locations:identifying gas leaks

Various sampling probes are also available, allowing leak detection at high or narrow locations and pinpoint measurement of specific locations.

For measurement on specific location For measurement on specific location

Product details

Portable 4Gas DetectorGX-Force

  • Lightweight design weighing approximately 300g
    with an easy-to-grip grip design
  • 3-year sensor warranty
  • Continuous use time Approx. 30 hours
  • Passed 3m drop test
  • Explosion-proof and explosion-proof construction
  • Protection rating equivalent to IP67
Portable 4Gas Detector GX-Force

Development background

Our gas detector performance has improved to allow safe and secure use across a variety of sites.

GX-Force was created with the aim of developing reflecting the views expressed at usage sites to achieve a high degree of satisfaction at all sites.

Extensive international network
for reliable and complete support

Utilizing our established overseas network, you could purchase
our product and services all over the world.

About us

Since our company was founded in 1939 under the umbrella conglomerate of RIKEN, our management philosophy has been to create safe working environments. Our science and technology research laboratories have developed industrial gas detection warning devices, specializing in monitoring harmful gases in the work environment, as well as for explosion prevention from combustible gases. Without compromise, we continue to challenge ourselves to be technological leaders, developing and manufacturing a wide range of industrial gas detection systems and monitors. From large-scale gas detecting alarm systems to small-sized personal gas monitors for safety protection; used in many industries including semiconductor and LCD plants, petroleum complexes, steelworks, various tankers, oil storage stations, underground gas facilities, and volcanoes.

image for over 80 years

Experts in gas detection for over 80 years

The “RIKEN Gas Detector” utilizing the principle of light wave interference, was exhibited at the 1937 Paris World Exposition. Its subsequent use greatly contributed to the prevention of accidents in coal mines where many fatalities were prevalent at the time. On the 15th March 2019 we celebrated our 80th anniversary. Supported by our history and tradition we shall further improve long established technology, and continue to innovative. Developing reliable quality products in response to the diverse needs of industry.